SPECIFICATIONS 24 volt SeriousAir:

Size:* L 405mm x W 150mm x H 252mm            (Standard configuration)
                            or
      L 405mm x W 207mm x H 230mm (Rotated configuration – can be  ordered)

Weight: 15.4 kg (Not including hoses and cables )

Capacity: Unrestricted, 458 Ltr/min   (16.2 cu ft/min)   

At 80 PSI (560 Kpa) pumping tyre               344  Ltr/min   (12.2 cu ft/min)

Current draw: No load: Through Nitto type “Quick connect” fitting on outlet = 75-80 Amp.
                          Loaded:   Pumping through 10metre hose and tyre valve   = 125-130 Amp.

RPM:  Unloaded:     = 4800 RPM

         Loaded:   pumping at 80 PSI 
                   (560 Kpa) = 3460 RPM

Temperature: After 3 minutes continuous pumping (ambient temp 20 deg C):    
         Motor = 38 degrees C.
           Compressor (motor end) 60 Deg C;                          Discharge Port 130 deg C.

Performance: 
(1)Pumping into “Cooper ST” 285 x 75-R16  (through tyre valve) 36 seconds 0-29 psi  (0 - 203 Kpa)

  54 seconds  0 - 45 psi  (0 - 315 Kpa)

(2)Pumping into “Bridgestone #693” 
    265 x 75  R16 (through tyre valve)          1minutes 12 seconds= 64 PSI (0- 448 Kpa)

(3) Pumping Semi-trailer tyres using    Nitto free flow adapter (Supplied with  compressor):                                      Tyre size:  D660 x 22.5R “Dunlop”:   2.7 minutes 0 – 100 PSI  (0 – 700 Kpa)

 (4) Tyre size:  295 x 80 x 22.5R “Yokohama”  (Semi Trailer Tyre):    
   3.0 minutes  =  0 – 100 PSI ( 0 -700 Kpa)

Duty Cycle:  In well ventilated spaces    using “Nitto” free-flow adapter
  (Supplied with compressor) = 80%

Typical Use: Pump up 4 tyres from
16 - 36PSI (112 - 252 Kpa) takes 4 x 18 sec
          = 1minute 12 seconds of use.

Note : The 24 volt compressor looks exactly the same as the 12 volt one.

If supplied for use with a receiver  (air tank) the overall height will be 20 mm less since the deeper base housing the remote control receiver electronics is not required.
A pressure switch on the receiver tank controls the switching operations in this configuration.